Configuration

Checking the System

1.Highlight System Check in the Main menu and press . The System Check (Config.) screen appears.

Figure 3-13 System Check (Config.) Screen

2.Highlight the field under the On/Off heading for the desired category and press

to toggle between On and Off. When turned On, the DVR reports a fault condition if it does not detect any recording or if there is no alarm during the designated time.

3.Highlight the field under the Interval heading and press . A slide bar appears allowing you to set the check interval from 1 hour to 30 days.

The Status field displays Good if:

the DVR is operating according to the user's settings without any problems

there was recording

OR

any alarm occurred during the designated time

The Status field displays Bad if there was no recording during the designated time, or no alarm occurred during the designated time.

Setting Up Alarm Out/Notify

1.Highlight the Alarm Out/Notify tab and press . The System Check Alarm Out/Notify screen appears.

Document 800-00919 Rev F

45

02/08