Tap the
Start > Settings > Control Panel > Power
The Thor VM2 power mode timers are cumulative.
The System Idle timer begins the countdown after the User Idle timer has expired and the Suspend timer begins the count- down after the System Idle timer has expired.
When the User Idle timer is set to “Never”, the power scheme timers never place the device in User Idle, System Idle or Suspend modes (even when the device is idle).
The Display > Backlight setting is synchronized with the User Idle setting in the Schemes tab in the Power control panel.
Factory Default Settings
Battery | No user interaction |
|
|
| |
|
|
|
|
| |
Schemes | The default power schemes are |
|
|
| |
|
|
|
|
|
|
| AC/DC | Ignition Control/ | Ignition Control/ | Auto On | UPS |
|
| Ignition On | Ignition Off |
|
|
|
|
|
|
|
|
User Idle Timeout | 15 minutes | 15 minutes | 1 minute | 15 minutes | 30 seconds |
|
|
|
|
|
|
System Idle Timeout | 1 hour | 1 hour | 5 minutes | 1 hour | 1 minute |
|
|
|
|
|
|
Suspend Timeout | 8 hours | 8 hours | 1 hour | 8 hours | 10 minutes |
|
|
|
|
|
|
Shutdown Timeout | Never | Never | 8 hours | Never | 20 minutes |
|
|
|
|
|
|
Device Status | No user interaction |
|
|
| |
|
|
|
|
|
|
5 - 78