LED Behavior

System State

 

 

 

Off

Suspend

External power not present

Off

 

 

Green blinking slowly

CPU temperature less than -20ºC, Heater warming CPU for 30 sec.

External power present

 

 

(1/2 sec. on, 1 1/2 sec. off)

 

 

 

 

Green blinking slowly

CPU temperature less than -20ºC, Need to move unit to warmer environment

External power not present

 

 

(1/2 sec. on, 1 1/2 sec. off)

 

 

 

 

 

UPS Status LED

The color of the UPS LED identifies the charge level, while the behavior of the LED identifies the charging state.

Charge Level

LED Color

Status

 

 

Green

Fully charged (>90%)

 

 

Amber

• Less than fully charged, but more than 2 minutes runtime remaining

 

Out of Safe Charging Temperature Range (page 3-3)Charging only occurs between

 

 

approximately -10°C and 35°C ambient temperature

 

No UPS present

 

Charging Timeout (page 3-3)Not fully charged after 4 or 8 hours depending on software

 

 

revision.

 

 

Red

Low battery, less than 2 minutes runtime until shutdown

 

 

 

Charging State

 

LED Behavior

Status

 

 

 

 

 

 

Slow Blink

 

Charging

 

(1 sec. on, 3 sec. off)

 

 

 

 

 

 

 

 

Fast Blink

 

UPS supplying power and discharging

 

(1/2 sec. on, 1/2 sec. off)

 

 

 

 

 

 

 

 

On

 

Neither charging or discharging

 

 

 

 

 

 

Off

 

Unit is off or is in Suspend

 

 

 

 

 

SSD (Solid State Drive) LED

 

 

 

 

LED Behavior

Status

 

 

 

 

 

Flashing Green

SSD read or write activity

 

 

 

 

Off

No SSD read or write activity

 

 

 

 

 

 

3 - 12