Wiring Diagram

Existing Circuitry on Vehicle

Quick Mount

Smart Dock

Forklift Battery

Main Switch

User supplied serial

+Vo -Vocable for optionalCOM1 or COM2 screen blanking

Fuse - See

connection,

Connector

Warning

see below

 

 

 

statement below

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

See Caution

 

 

 

 

 

 

 

 

 

 

 

 

 

 

statement below

 

+

 

-

 

 

 

 

Red/White (if present)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+

 

 

Red

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Black/White (if present)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Black

 

 

Power

 

 

 

 

 

 

 

 

 

 

-

 

 

 

Connector

 

 

 

 

 

 

 

 

 

 

 

 

Green

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DC/DC

 

 

 

 

 

Blue

 

 

 

 

 

 

 

Power

 

 

 

 

 

(not connected)

 

 

 

 

 

 

 

 

Supply

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

!CAUTION

For battery powered vehicles:

must be connected to the vehicle chassis ground.

For internal combustion engine powered vehicles:

is connected to the vehicle chassis ground, which can also be battery negative.

!WARNING

For proper and safe installation, the input power cable must be connected to a fused circuit on the vehicle. If the supply connection is made directly to the battery, the fuse should be installed in the positive lead within 5 inches of the battery’s positive (+) terminal. The fused circuit requires a maximum time delay (slow blow) fuse with a current rating as noted below.

For 60VDC input, use a 6A slow blow fuse that has a DC voltage rating greater than 60VDC.

For 72VDC input, use a 6A slow blow fuse that has a DC voltage rating greater than 72VDC.

For 96VDC input, use a 4A slow blow fuse that has a DC voltage rating greater than 96VDC.

For 108VDC input, use a 4A slow blow fuse that has a DC voltage rating greater than 108VDC.

For 120VDC input, use a 4A slow blow fuse that has a DC voltage rating greater than 120VDC.

For 132VDC input, use a 3A slow blow fuse that has a DC voltage rating greater than 132VDC.

For 144VDC input, use a 3A slow blow fuse that has a DC voltage rating greater than 144VDC.

Note: For North America, a UL Listed fuse is to be used.

4 - 46