Thor VM2 is installed on a powered Quick Mount Smart Dock with the dock power switch On

Thor VM2 is already mounted to a dock and external power is applied to the dock

Thor VM2 is already mounted to a dock and the dock power switch is turned On

Result

The Thor VM2 continues to run and follows the Auto-On power scheme with timers reset at the time power was connected.

UPS Mode

This mode is selected any time external power is not present, regardless of selected Power Configuration. Ignition Input is ignored.

Thor VM2 is Off

Conditions

The Thor VM2 is Off and the power button is pressed the Thor VM2 and both the following conditions are met:

UPS power is over 10% capacity

CPU temperature is over 20ºC

Result

The Thor VM2 boots and follows the UPS power scheme with power management timers reset at boot up.

Conditions

The Thor VM2 is Off and the power button is pressed the Thor VM2 and at least one of the following conditions are met:

UPS power is under 10% capacity

CPU temperature is under 20ºC

Results

The Thor VM2 remains Off.

Thor VM2 is On

Conditions

The Thor VM2 is On and external power is removed, such as:

Thor VM2 is removed from a powered dock (Dock power switch On)

Thor VM2 is mounted to a dock and truck power is removed from the dock

Thor VM2 is mounted to a dock and the dock power switch is turned Off

Result

The Thor VM2 continues to run and follows the UPS mode power scheme with power management timers reset at the time of power removal. UPS charging is disabled.