HP 8-Channel 196 kSa/sec Digitizer plus DSP E1433A 64000 65536 76800, 076294, 078125, 091553

Models: 8-Channel 196 kSa/sec Digitizer plus DSP E1433A

1 220
Download 220 pages 41.78 Kb
Page 57
Image 57

HP E1433A User's Guide

Using the HP E1433A

Table of Baseband Measurement Spans (part 2 of 4)

All values in Hertz.

sample

 

 

 

 

 

 

frequency

64000

65536

76800

(Fs) —>

 

 

 

 

 

 

number of

 

without

 

without

 

without

divide-by-2

with divide-by-5

with divide-by-5

with divide-by-5

divide-by-5

divide-by-5

divide-by-5

steps

 

 

 

 

 

 

 

 

 

0

5000.000000

25000.000000*

5120.000000

25600.000000*

6000.000000

30000.000000*

1

2500.000000

12500.000000

2560.000000

12800.000000

3000.000000

15000.000000

2

1250.000000

6250.000000

1280.000000

6400.000000

1500.000000

7500.000000

3

625.000000

3125.000000

640.000000

3200.000000

750.000000

3750.000000

4

312.500000

1562.500000

320.000000

1600.000000

375.000000

1875.000000

5

156.250000

781.250000

160.000000

800.000000

187.500000

937.500000

6

78.125000

390.625000

80.000000

400.000000

93.750000

468.750000

7

39.062500

195.312500

40.000000

200.000000

46.875000

234.375000

8

19.531250

97.656250

20.000000

100.000000

23.437500

117.187500

9

9.765625

48.828125

10.000000

50.000000

11.718750

58.593750

10

4.882812

24.414062

5.000000

25.000000

5.859375

29.296875

11

2.441406

12.207031

2.500000

12.500000

2.929688

14.648438

12

1.220703

6.103516

1.250000

6.250000

1.464844

7.324219

13

0.610352

3.051758

0.625000

3.125000

0.732422

3.662109

14

0.305176

1.525879

0.312500

1.562500

0.366211

1.831055

15

0.152588

0.762939

0.156250

0.781250

0.183105

0.915527

16

0.076294

0.381470

0.078125

0.390625

0.091553

0.457764

Notes:

*For the top span the 3dB bandwidth is 1.15 times span shown.

To select a sample frequency for time domain data, first divide the desired sample frequency by 2.56 to convert it to a measurement span. Then locate the closest measurement span on this table and choose the corresponding sample frequency at top of the table.

3-19

Page 57
Image 57
HP 8-Channel 196 kSa/sec Digitizer plus DSP E1433A manual 64000 65536 76800, 076294, 078125, 091553