Code

Suggestions

03CCh

Run BIOS Setup and check the floppy drive

 

type. Rerun the test with another floppy disk.

 

Replace the floppy drive. Replace the

 

motherboard.

03EEh -

Check the connectors on the floppy drive,

03FFh

external module bay, and motherboard. Rerun

 

the test with another floppy disk. Replace the

 

floppy drive. Replace the motherboard.

Keyboard Tests

0400h -

Replace the motherboard.

0401h

 

0410h -

Check the keyboard flex cable connection.

0414h

Replace the keyboard. Replace the

 

motherboard.

0415h

Replace the motherboard.

0416h -

Replace the keyboard. Replace the

0418h

motherboard.

Serial Port Tests

0601h

For the external loopback test, make sure the

 

loopback connector is installed and constructed

 

properly. For the external or internal loopback

 

test, replace the motherboard.

0602h

Replace the motherboard.

0603h

For the external loopback test, make sure the

 

loopback connector is installed and constructed

 

properly. For the external or internal loopback

 

test, replace the motherboard.

0604h -

Replace the motherboard.

0605h

 

0606h

For the external loopback test, make sure the

 

loopback connector is installed and constructed

 

properly. For the external or internal loopback

 

test, replace the motherboard.

0607h

Make sure the loopback connector is installed

 

and constructed properly. Replace the

 

motherboard.

0608h -

Replace the motherboard.

0617h

 

Parallel Port Tests

0701h

For the external loopback test, make sure the

 

loopback connector is installed and constructed

 

properly. For the external or internal loopback

 

test, replace the motherboard.

0702h

For DiagTools 2.2, replace motherboard. For

 

earlier version, no repair (printer test not

 

supported).

0703h

Run BIOS Setup and disable ECP for the

 

parallel port, then rerun the test. Replace the

 

motherboard.

0704h -

Replace the motherboard.

0706h

 

0707h

Connect the loopback connector.

0708h

Replace the motherboard.

Audio Tests

0801h -

If this error also occurs for an external

08C2h

headphone, replace the motherboard.

 

Otherwise, check the speaker connection,

 

replace the speaker. If it occurs only for an

 

external headphone, replace the motherboard.

08D0h-

Replace the motherboard.

08F3h

 

Code

Suggestions

9003h -

(See Microphone Tests near end of table.)

9004h

 

9018h –

(See NMA Sound Tests near end of table.)

901Ah

 

Video Tests

0900h -

Replace the motherboard.

0920h

 

8000h,

(See LCD Tests near end of table.)

9016h -

 

9017h

 

CD-ROM Tests

0A00h

Insert a CD in the drive.

0A01h

Rerun the test. Replace the CD-ROM drive.

0A02h

No repair. (Automatic close not supported.)

0A03h

Insert a different CD in the drive. Check the

 

connectors on the CD-ROM drive, external

 

module bay, and motherboard. Replace the

 

CD-ROM drive.

0A04h

Insert a computer CD in the drive.

0A05h

Insert a different CD in the drive. Check the

 

connectors on the CD-ROM drive, external

 

module bay, and motherboard. Replace the

 

CD-ROM drive.

0A06h

Insert a computer CD in the drive. Replace the

 

drive.

 

For earlier diagnostics, insert an audio CD in

 

the drive.

0A07h

Rerun the test. Replace the drive.

0A08h

Insert an audio CD. Replace the drive.

0A09h

Rerun the test. Replace the drive.

0A10h

Insert an audio CD. Replace the drive.

0A11h

Rerun the test with an audio CD. Replace the

 

drive.

0A12h

Insert a different multisession CD. Replace the

 

drive.

SMBus Tests

0E00h -

Replace the motherboard.

0E10h

 

ATAPI Removable Tests (LS-120)

0F01h

Connect the LS-120 drive an rerun the test.

0F02h -

Rerun the test. Insert a different disk in the LS-

0F03h

120 drive. Check the connectors on the LS-120

 

drive, external module bay, and motherboard.

 

Replace the LS-120 drive.

0F04h -

Replace the LS-120 drive.

0F05h

 

0F06h

Rerun the test. Insert a different disk in the LS-

 

120 drive. Check the connectors on the LS-120

 

drive, external module bay, and motherboard.

 

Replace the LS-120 drive.

0F07h

Replace the LS-120 drive.

0F08h

Rerun the test. Insert a different disk in the LS-

 

120 drive. Check the connectors on the LS-120

 

drive, external module bay, and motherboard.

 

Replace the LS-120 drive.

0F09h

Replace the LS-120 drive.

TI CardBus Tests

1201h

Memory space not available. Remove any

 

attached ISA or PCI cards.

3-16 Troubleshooting and Diagnostics

HP OmniBook 900

Page 66
Image 66
HP Book 900 manual Video Tests