POST Error Messages

Numeric Codes and Text Messages (Continued)

Code/Message

Probable Cause

Recommended Action

Warning: CPU fan

CPU Fan weak (RPM <

has failed.

1000) or not turning.

Ensure that the CPU fan power cable is connected. If the problem persists, contact an authorized service center for assistance.

Warning: System

System Fan weak (RPM <

Fan has failed.

1000) or not turning.

Ensure that the System fan power cable is connected. If the problem persists, contact an authorized service center for assistance.

Memory is running

When two same size

at Single Channel

memories are put in slot

Mode

1 and 3, this message

 

will be displayed.

For optimal performance, shut down the system and move the second DIMM from the XMM3 to the XMM2 socket.