Installing the HP
E1459A in a
VXIbus Mainframe
1Set the extraction levers out.
2
Slide the module into any slot (except slot 0) until the backplane connectors touch.
Extraction
Levers
3 Seat the module into the mainframe by pushing in the extraction levers
4Tighten the top and bottom screws to secure the module to the mainframe.
NOTE: The extraction levers will not seat the backplane connectors on older VXIbus mainframes. You must manually seat the connectors by pushing in the module until the module's front panel is flush with the front of the mainframe.
The extraction levers may be used to guide or remove the module.
To remove the module from the mainframe, reverse the procedure.
Figure
WARNING To prevent electric shock, tighten faceplate screws when installing module into mainframe.
24 Installing and Configuring the HP E1459A