Control panel message

Description

Recommended action

 

 

 

 

2204-Inventory error during MEBx execution

BIOS information passed to the MEBx

1.

Reboot the computer.

 

resulted in a failure.

2.

If the error persists, update to the latest

 

 

 

 

 

BIOS version.

 

 

3.

If the error still persists, replace the

 

 

 

system board.

 

 

 

 

2205-Interface error during MEBx execution

MEBx operation experienced a hardware

1.

Reboot the computer.

 

error during communication with ME.

2.

If the error persists, update to the latest

 

 

 

 

 

BIOS version.

 

 

3.

If the error still persists, replace the

 

 

 

system board.

 

 

 

2211-Memory not configured correctly for

DIMM1 or XMM1 is not installed.

Make sure there is a memory module in the

proper MEBx execution.

 

black DIMM1 socket and that it is properly

 

 

seated.

2212-USB Key Provisioning failure writing to device

USB device used for USB key provisioning

1.

Try a different USB key device for

will not allow BIOS to update provision file

 

provisioning.

properly.

2.

If the error persists, update to the latest

 

 

 

BIOS version and ME firmware version.

 

3.

If the error still persists, replace the

 

 

system board.

2217-ME Firmware Version request failure

ME firmware is not properly responding to

1.

Reboot the computer.

 

BIOS query for version information.

2.

If the error persists, update to the latest

 

 

 

 

 

BIOS version and ME firmware version.

 

 

3.

If the error still persists, replace the

 

 

 

system board.

2218-ME Firmware Version should be updated

ME firmware must be updated to match current functionality contained in the system BIOS.

1.Update to the latest ME firmware version.

2.If the error persists and system BIOS has been recently updated, restore previous system BIOS version.

3.If the error still persists, replace the system board.

2219-USB Key Provisioning file has invalid header identifier

Provisioning file contained on the USB key has been corrupted or is not a valid version for the current ME firmware.

1.Recreate the provisioning file using third party management console software.

2.If the error persists and system BIOS has been recently updated, restore previous system BIOS version. Otherwise, update the ME firmware version.

3.If the error still persists, replace the system board.

244 Chapter 10 POST error messages

Page 256
Image 256
HP 800 G1 E1Z89UTABA, E1Z84UT E1Z84UT#ABA, 800 G1 E3T09UT#ABA manual If the error persists, update to the latest