Discovery from HP SIM - Click Options > Storage Essentials > Discovery > View Logs.

2.On the View Logs page, click the “Click here” portion of the following message:

Click here if you wish to stop getting details.

3.When you are asked if you are sure you want to stop Get Details/Discovery Data Collection, click OK.

The management server stops gathering details.

4.Schedule a time to resume getting details.

Excluding EMC Symmetrix Storage Systems from Force Device Manager Refresh

The management server obtains most of its information about Symmetrix storage systems from the EMC Solutions Enabler (proxy server) it discovered. If the EMC Solutions Enabler does not have the latest information, the management server also displays the outdated information.

To make the management server aware of any changes, make sure the Solutions Enabler it discovered has the latest information. This can be done by forcing the Solutions Enabler to refresh its data. The management server is then made aware of these changes.

When the Force Device Manager Refresh option is selected, the management server refreshes discovered EMC Solutions Enabler (proxy server), unless specified. If you do not want an EMC Solutions Enabler to be refreshed, you must assign the Symmetrix storage systems that use the Solutions Enabler to the cimom.emc.skipRefresh property, as described in the steps in this section.

To exclude EMC Symmetrix storage systems from a forced refresh:

1.Select Options >Storage Essentials > Manage Product Health > Advanced.

2.Click Show Default Properties at the bottom of the page.

3.Copy the following command. How you copy the text depends on your Web browser. If you are using Microsoft Explorer or Netscape Navigator, select the text and then right-click the selected text. Then, select Copy.

#cimom.emc.skipRefresh=000183500570,000183500575

4.Return to the Advanced page (Options >Storage Essentials > Manage Product Health > Advanced).

5.Paste the copied text into the Custom Properties field. How you paste the text depends on your Web browser. If you are using Microsoft Explorer or Netscape Navigator, right-click the field and select Paste.

6.Make sure the property is not commented out by removing the hash (#) symbol in front of the property. Add the serial numbers corresponding to the Symmetrix storage systems you want the refresh to skip. Separate additional serial numbers with a comma, as shown by the following example:

cimom.emc.skipRefresh=000183500570,000183500575

where 000183500570 and 000183500575 are serial numbers for Symmetrix storage systems. One of the ways to find the serial number is to double-click the storage system in System Manager. Then, click the Properties tab.

Storage Essentials 5.00.01 User Guide 83