Java Applet Has Data from a Different Version of Management Server Software

If you attempt to monitor a host with old JAR (Java Archive) files, you might be unable to monitor the host and you might see the following error message:

The Java applet has data from a different version of the management server. Please close and re-start your browser.

The reason for this error message is that the client still has JARs from the previous build in its Java Plug-in cache. To remove the old JARs, clear the cache for the Java plug-in.

OutOfMemoryException Messages

In some rare cases it may be necessary to increase the amount of memory for the Java plug-in on the client computer. This should only be done if you are seeing OutOfMemoryException messages in the Java console on the client side.

Improving Reload Performance in System Manager

If your Java plug-in control panel cache setting is set at 50 MB, it is recommended you increase this setting to 150 MB or more. Increasing this setting improves the reloading performance of System Manager.

Troubleshooting Provisioning

This section describes the following:

Cannot Access a Resource Owned by Another Controller” on page 626

Error -56 on page 626

“Can't delete this zone” Message” on page 627

Changes in EFC Manager Requiring Discovery Data Collection/Get Details” on page 627

Cannot Access a Resource Owned by Another Controller

You received the message about not being able to access a resource owned by another controller because you tried to access a controller that has not been discovered. You should discover all controllers on the Engenio storage system.

For example, assume you discovered only one of the controllers on an Engenio storage system with two controllers. If you want to change a volume, such as add or delete a LUN, you will not be able to make the change to the volume associated with the controller that has not been discovered.

See Discovering Filers, Tape Libraries, Switches and Storage Systems” on page 15 for more information on how to discover a controller.

Error -56

If you see error -56, the switch has network connection failures/problems. To solve the problem, make sure the switch is physically connected to the network. Then, redo the task you were originally trying to complete.

If you now see -21(OBJECT_NOT_FOUND)errors, the switch needs to be rediscovered.

626 Troubleshooting