Table 140 Known Device Issues (continued)
Device | Software | Description |
|
|
|
IBM | Subsystem | If you discovery an IBM storage system without SDD, incorrect |
Storage | Device Driver | stitching is displayed in System Manager for the storage system. You |
Systems | (SDD) or | are shown only one path if the storage system is using MPIO instead |
| MPIO (Multi | of SDD. |
| Pathing IO) |
|
|
|
|
“mailbox command 17 failure status FFF7” Message
If one or more of your Microsoft Windows hosts are using an Emulex HBA driver, you may see the following message in Windows Event Viewer:
“mailbox command 17 failure status FFF7”
This message can be safely ignored. The HBAAPI is being used to access data in the FLASH memory of the adapter that does not exist and this is causing the event to be logged. This issue has been seen with version 5.2.2 of the driver.
”Process Has an Exclusive Lock” Message
You will receive a message resembling the one shown below if a process has already locked the EMC Symmetrix storage system and you attempt a process that requires a lock on the Symmetrix storage system. The Symmetrix storage system can become locked for many reasons. For example, the storage system becomes locked when it performs LUN mapping, LUN masking or Discovery Data Collection/Get Details. The Symmetrix storage system may also remain locked after a provisioning operation has failed.
“SYMAPI routine SymDevMaskSessionStart failed with error code 188: The operation failed because another process has an exclusive lock on the local Symmetrix.”
After the management server has detected the lock on the Symmetrix storage system, it tries to access the storage system for 15 minutes and logs the errors.
If you receive the error message, determine if someone is performing an operation that requires a lock, such as LUN mapping, LUN masking or Discovery Data Collection/Get Details. This also applies even if one of the processes is being used by a
Storage Essentials 5.00.01 User Guide 631