EasyCoder 3400e Bar Code Label Printer User’s Manual
RS-422  Serial Interface
Use the 
RS-485  Serial Interface
Use the 
| Interface | Pin No. | Name | Operation | 
| 1 | Chassis Ground | Connect to pin 1, chassis ground, of connected device. | |
| 
 | 
 | (GND) | 
 | 
| 2 | Transmit Data | Output: Connect to receive data pin of connected device. | |
| 
 | 
 | (TD) | 
 | 
| 3 | Receive Data | Input: Connect to transmit data pin of connected device. | |
| 
 | 
 | (RD) | 
 | 
| 4 | Request to Send | Output: When you use a modem, connect to modem RTS pin. | |
| 
 | 
 | (RTS) | The modem sets RTS to true before transmission. The printer | 
| 
 | 
 | 
 | sets RTS to false after transmission. | 
| 5 | Clear to Send | Input: When you use a modem, connect to modem CTS pin. The | |
| 
 | 
 | (CTS) | modem must set CTS true before the printer transmits data. If not | 
| 
 | 
 | 
 | connected, CTS sets itself true. | 
| 7 | Signal Ground | To enable communications, connect to signal ground of | |
| 
 | 
 | (SG) | connected device. Completes circuit for all  | 
| 11 | Printer Status (PS) | Output: When not using software flow control (XON/XOFF), | |
| 
 | 
 | 
 | connect to input of connected device (for example, CTS). | 
| 
 | 
 | 
 | Indicates printer mechanical status and status of printer input | 
| 
 | 
 | 
 | buffer. | 
| 13 | Input B | Input: Serial differential data to the printer. | |
| 14 | Output A | Output: Serial differential data from the printer. | |
| 16 | Input A | Input: Serial differential data to the printer. | |
| 19 | Output B | Output: Serial differential data from the printer. | |
| 20 | Data Terminal | Output: When you use a modem, connect to modem DTR pin. | |
| 
 | 
 | Ready (DTR) | 
 | 
When using Intermec Standard Protocol, this pin indicates that the printer is switched on.
When using XON/XOFF or hardware flow control, this pin indicates the printer mechanical status and the status of the printer input buffer.