Table 1. Numeric error codes (continued)
Symptom or error | FRU or action, in sequence | |
|
|
|
1804 | 1. | Remove the WAN card that you |
Unauthorized WAN card is plugged |
| installed. |
2. | System board. | |
|
|
|
1805 | 1. | Remove the Wireless USB card that you |
Unauthorized Wireless USB card is plugged |
| installed. |
2. | System board. | |
card. |
|
|
|
| |
1820 | Remove all but the reader that you set up | |
More than one external fingerprint reader is | for the authentication. | |
attached. Power off and remove all but the |
|
|
reader that you set up within your main |
|
|
operating system. |
|
|
|
| |
1830 | Install DIMM in | |
Invalid memory | Note: For the construction of the DIMM | |
and install a memory module to | slot, see “1050 DIMM” on page 72. | |
the lower slot. |
|
|
|
|
|
2000 | 1. | Undock docking station or port |
Hard Drive Active Protection sensor |
| replicator if it is attached to the |
diagnostics failed.Press <Esc> to |
| ThinkPad computer. |
continue.Press <F1> to enter SETUP | 2. | Place the ThinkPad computer on a |
|
| horizontal surface. Do not apply any |
|
| physical shock to the computer. |
| 3. | Run Diagnostics |
|
|
|
|
| |
2010 | Inform the following information to the | |
Warning: Your internal hard disk drive | customer: If in the primary bay the customer | |
(HDD) may not function correctly on this | is using a | |
system. Ensure that your HDD is supported | drive (HDD), or an old generation IBM | |
on this system and that the latest HDD | HDD which is not supported by this system, | |
firmware is installed. | with the risk in mind, the customer can still | |
| use it by pressing ESC. If in the primary | |
| drive bay the customer is using a supported | |
| IBM/Lenovo HDD with an old firmware, | |
| the customer needs to update its firmware to | |
| the latest. The latest version is available at | |
| http://www.lenovo.com/support | |
|
|
|
2100 | 1. | Reseat the hard disk drive. |
Initialization error on HDD0 (Main hard | 2. | Main hard disk drive. |
disk drive) | 3. | System board. |
|
|
|
2102 | 1. | Reseat the hard disk drive. |
Initialization error on HDD1 (Ultrabay hard | 2. | Ultrabay™ hard disk drive. |
disk drive) | 3. | System board. |
|
|
|
2110 | 1. | Reseat the hard disk drive. |
Read error on HDD0 (Main hard disk drive) | 2. | Main hard disk drive. |
| 3. | System board. |
|
|
|
2112 | 1. | Reseat the hard disk drive. |
Read error on HDD1 (Ultrabay hard disk | 2. | Ultrabay hard disk drive. |
drive) | 3. | System board. |
|
|
|