Define

Action for Output Spooled File

Sequence

:

10

 

Text

:

QSYSPRT spool in OUTQ1

Action

:

1

/ 1

Panel

:

1

/ 2

Type choices, press

Enter.

 

 

User exit before .

. .

*NONE

Name, *NONE

Library

. .

 

Name, *LIBL

User parameter .

. .

 

Value

Print Definition .

. .

SAMPLE

Name, *SPOOLFILE, *NONE

Library

. .

*PRTDEFLIB

Name, *PRTDEFLIB, *LIBL

Run option . . .

. .

*NORMAL

*NORMAL, *NOCOPY, *REPRINT

User exit middle .

. .

*NONE

Name, *NONE

Library

. .

 

Name, *LIBL

User parameter .

. .

 

Value

Output device . . .

. .

*JOB

Name, *JOB

Output queue . . .

. .

PRT01

Name, *DEV, *SPOOLFILE

Library

. .

*LIBL

Name, *LIBL

====>

 

 

 

F12=Cancel

 

F15=Next action

Figure 107. Define Action for Output Spooled File panel

On this panel, you specify the name, library, and user-defined parameter for the program that APU is to call before, during, or after processing. The default is *NONE. Refer to Appendix B, ªUser Exitsº on page 103 for details about the user exits.

The Print Definition lines contain values for the library where the print definition is stored, and for the ªRun Option.º

Following are the values that could be entered for Run Option:

Ignored

If you specify *NONE on the print definition field, any value you place here is ignored.

*NORMAL

This is the default entry. If only one action (of 16) is defined, *NORMAL is the only valid value for the field, so the value must be *NORMAL for the first (or only) action.

*NOCOPY

This value is valid only if specified for the second (or later) action group. It allows different print definitions for the same spooled file.

*REPRINT

This value is valid only if specified for the second (or later) action. This value is used if you want to apply the same print definition multiple times on the same spooled file.

In the output device field, you specify the name of the device on which the spooled file is to be printed. The value *JOB gets APU to place the output spooled file in the out-queue of the current device.

The output queue field contains the name of the output queue where the spooled file is to be placed. *SPOOLFILE tells APU to place the output file in the same

Chapter 6. Automatic Printing with APU Monitor 95

Page 107
Image 107
IBM S544-5351-03 manual Sample, Prtdeflib, PRT01