7 SET MODE
■General
Set mode is used for programming infrequently changed values or conditions of functions. The IC- 706MKIIG has 2 separate set modes: quick set mode and initial set mode.
DQuick set mode operation
➀While power is ON, push [DISPLAY] for 2 sec.
•Quick set mode is selected and one of its items appears.
•Quick set mode items vary depending on the operating mode (SSB, FM, etc.) selected.
➁Push [MENU] one or more times to select the
desired item.
•
➂Rotate the main dial to set the values or conditions for the selected item.
➃Repeat steps ➁ and ➂ to set other items.
➄To exit quick set mode, push [DISPLAY] momentar- ily.
DInitial set mode operation
➀Push [POWER] for 2 sec. to turn power OFF.
➁While pushing [LOCK] push [POWER] to turn power ON.
•Initial set mode is selected and one of its items appears.
➂Push [MENU] one or more times to select the desired item.
•
➃Rotate the main dial to set the values or conditions for the selected item.
➄Repeat steps ➂ and ➃ to set other items.
➅To exit initial set mode, push [POWER] for 2 sec. to turn power OFF.
➆Push [POWER] to turn power ON again.
•The conditions selected in initial set mode are now effec- tive.
[POWER] |
|
|
| Main dial | |||||
|
|
|
|
|
|
|
|
| [Y] |
|
|
|
|
|
|
|
| [Z] | |
|
|
|
|
|
|
|
|
| |
|
|
|
|
| [MENU] | [DISPLAY] | |||
[DISPLAY EXAMPLE: QUICK SET MODE] | |||||||||
|
|
| USB |
|
|
|
|
| |
|
|
|
|
|
|
|
|
| Value or |
S1 | 3 | 5 | 7 | 9 | 20 | 40 | 60dB |
| condition |
PO |
|
|
|
| 5 |
| 10 |
|
|
Q1 |
|
| RF POWER | Item |
Item number
[POWER] | Main dial |
| [Y] |
[Z] | |
| |
[MENU] | [LOCK] |
[DISPLAY EXAMPLE: INITIAL SET MODE]
Value or condition
1 MODE SELECT Item
Item number
47