INSTALLATION AND CONNECTIONS 2

External antenna tuners and linear amplifier

CONNECTING THE AH-4

 

Coaxial cable

 

The AH-4 can be used for the HF bands and 50

 

 

MHz band only.

 

ANT 1

(from the AH-4)

 

AH-4

 

 

 

 

 

 

 

 

To the AH-2b or

Transceiver

 

 

an antenna element

 

 

 

CONNECTING THE AT-180

ACC cable supplied with the AT-180

 

Coaxial cable supplied

HF

 

 

to 6 m

with the AT-180

 

 

 

 

 

 

antenna

 

 

 

 

 

[ANT 1]

[ACC]

AT-180 [ACC]

one of two

 

connectors

IC-706

[TRANSCEIVER]

Ground

Note:

• Turn the IC-706MKIIG’s power

OFF when connecting the AT-

Do not connect [ANT 2] to the AT-180. When using an HF to 2 m wide antenna, use a duplexer

Transceiver

AT-180

HF to 2 m antenna

180, otherwise, the CPU may

malfunction and the AT-180

may not function properly.

• The OPC-742 is required when

using both the AT-180 and a 2

m linear amplifier.

between the AT-180 and antenna since 2 m signals do not pass through the AT-180.

[ANT 1]

[ANT 2]

Duplexer

CONNECTING THE IC-PW1

 

 

 

 

To an

Mini-plug cable

OPC-599 conversion cable

 

 

antenna

 

 

 

 

 

 

 

ACC cable

 

 

 

 

 

 

 

 

7-pin side

 

 

ANT

ACC-1

REMOTE

 

 

ACC

REMOTE

 

 

 

INPUT-1

ANT1

 

 

 

 

 

 

 

 

Coaxial cable

 

 

 

 

 

 

 

GND

Transceiver

 

 

 

 

GND

 

 

 

 

 

IC-PW1

 

 

 

 

 

AC outlet (220–240 V)

 

 

 

14

 

 

 

 

 

 

Page 17
Image 17