STACK menu settings

3.7 Important information for Intelligent Stack (continued)

Example:

Cover Error: The lamp cover is open.

Lamp Error: The lamp will not light up.

Fan Error: There is a problem with the cooling fan.

Temp Error: The temperature of the projector is

too high.

Air Flow Error: The temperature of the projector is too high. Verify that the exhaust vents are not blocked.

Filter Error: The filter timer counter exceeds the hours set in the FILTER MESSAGE menu. (Operating Guide OPTION menu

SERVICE)

Cold Error: The temperature around the projector is too low.

If you need to turn off a projector in order to fix an error condition, turn off both the projectors so that Intelligent Stack can be started properly when the projectors are turned on again.

If the PIN LOCK or TRANSITION DETECTOR security function on both projectors is set to ON, both projectors will turn on. Enter the security code for Main first, then the security code for Sub. If ALTERNATE mode is selected, one of the projectors will turn off automatically. (Operating Guide SECURITY menu)

If the PIN LOCK or TRANSITION DETECTOR security function on one of the projectors is set to ON, it is necessary to enter the security code as follows when turning on the projector:

-In DUAL mode, both projectors will turn on. Enter the security code for the projector that is locked by the security function.

-In ALTERNATE mode, if the projector locked by the security function is due to turn on according to the ALTERNATE mode setting, only that projector will turn on. Otherwise, both projectors will turn on. Enter the security code for the projector that is locked by the security function. After the security lock is released, one of the projectors will turn off if both projectors are turned on.

22

Page 22
Image 22
InFocus IN5142, IN5132, IN5134A, IN5135, IN5144A, IN5145 user manual Example, Service