Intel NetStructure® MPCBL0001 High Performance Single Board Computer 165
Technical Product Specification
List of Supported Commands (IPMI v1.5 and PICMG 3.0)
SDR Device Commands
Command NetFn* CMD IPMI 1.5 Spec Func
Run Initialization Agent Storage 2Ch 27.21
SEL Device Commands
Command NetFn* CMD IPMI 1.5 Spec Func
Get SEL Info Storage 40h 25.2
Get SEL Allocation Info Storage 41h 25.3
Reserve SEL Storage 42h 25.4
Get SEL Entry Storage 43h 25.5
Add SEL Entry Storage 44h 25.6
Partial Add SEL Entry Storage 45h 25.7
Delete SEL Entry Storage 46h 25.8
Clear SEL Storage 47h 25.9
Get SEL Time Storage 48h 25.10
Set SEL Time Storage 49h 25.11
NOTE: *Refer to IPMI 1.5 Specifications for a detailed explanation on NetFn.
Table 98. PICMG 3.0 IPMI Supported Commands
Command Net Function Command Interface
Get PICMG Properties 2Ch 00h SMS/SMM/IPMB
Get Address Info 2Ch 01h SMS/SMM/IPMB
FRU Control 2Ch 04h SMS/SMM/IPMB
Get FRU LED Properties 2Ch 05h SMS/SMM/IPMB
Get LED Color Properties 2Ch 06h SMS/SMM/IPMB
Set FRU LED State 2Ch 07h SMS/SMM/IPMB
Get FRU LED State 2Ch 08h SMS/SMM/IPMB
Set IPMB State 2Ch 09h SMS/SMM/IPMB
Set FRU Activation Policy 2Ch 0Ah IPMB
Get FRU Activation Policy 2Ch 0Bh SMS/SMM/IPMB
Set FRU Activation 2Ch 0Ch SMS/SMM/IPMB
Get Device Locator Record ID 2Ch 0Dh SMS/SMM/IPMB
Set Port State 2Ch 0Eh IPMB
Get Port State 2Ch 0Fh SMS/SMM/IPMB
Compute Power Properties 2Ch 10h SMS/SMM/IPMB
Set Power Level 2Ch 11h IPMB
Get Power Level 2Ch 12h SMS/SMM/IPMB
NOTE: If a command is received over an invalid interface, a completion code of insufficient privilege level
(D4h) is returned.
Table 97. IPMI 1.5 Supported Commands (Sheet 3 of 3)