Hardware Management Overview

Table 4.

Sensor Thresholds for IPMC Firmware 1.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

System Event

 

 

 

 

 

 

 

 

Sensor Name

Sensor

Log, reported

Normal

LNR

LC

LNC

UNC

UC

UNR

 

Number

via CLI, SNMP,

Value

 

 

 

 

 

 

 

 

 

 

 

 

 

RPC, RMCP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+1.5

V

1Dh

Yes

+1.5 V

TBD

1.43

1.45

1.55

1.57

 

 

 

 

 

 

 

 

 

 

 

 

 

+2.5

V

17h

Yes

+2.5 V

TBD

2.3

2.36

2.625

2.7

 

 

 

 

 

 

 

 

 

 

 

 

 

+1.8

V

16h

Yes

+1.8 V

TBD

1.71

1.746

1.854

1.89

 

 

 

 

 

 

 

 

 

 

 

 

VTT DDR

15h

Yes

+1.25 V

TBD

1.185

1.20

1.3

1.315

 

(+1.25 V)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+1.2

V

14h

Yes

+1.2 V

TBD

1.14

1.176

1.224

1.26

 

 

 

 

 

 

 

 

 

 

 

 

 

+5 V

 

19h

Yes

+5 V

TBD

4.7

4.85

5.25

5.275

 

 

 

 

 

 

 

 

 

 

 

 

-12 V

1Bh

Yes

-12 V

TBD

-13.2

-12.6

-11.4

-10.8

 

 

 

 

 

 

 

 

 

 

 

 

+12 V

1Ah

Yes

+12 V

TBD

10.8

11.4

12.6

13.2

 

 

 

 

 

 

 

 

 

 

 

 

CPU Core

1Ch

Yes

+1.3 V

TBD

1.24

1.26

1.345

1.36

 

Voltage

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+3.3

V

18h

Yes

+3.3 V

TBD

3.102

3.201

3.465

3.482

 

 

 

 

 

 

 

 

 

 

 

 

 

+1.8

VSB

12h

Yes

+1.8 V

TBD

1.71

1.73

1.836

1.89

 

 

 

 

 

 

 

 

 

 

 

 

 

+3.3

VSB

10h

Yes

+3.3V

TBD

3.102

3.201

3.465

3.482

 

 

 

 

 

 

 

 

 

 

 

 

+5 VSB

11h

Yes

+5 V

TBD

4.09

4.19

5.25

5.275

 

 

 

 

 

 

 

 

 

 

 

 

VBAT

13h

Yes

+3 V

TBD

2.0

2.4

3.4

3.6

 

 

 

 

 

 

 

 

 

 

 

 

Board

30h

Yes

30

TBD

-5

5

60

70

 

Temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CPU 0

37h

Yes

40

TBD

5

10

76

81

 

Temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CPU 1

38h

Yes

40

TBD

5

10

76

81

 

Temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE: The following terms apply:

LNR: Lower Non-Recoverable

LC: Lower Critical

LNC: Lower Non-Critical

UNC: Upper Non-Critical

UC: Upper Critical

UNR: Upper Non-critical

Intel NetStructure® MPCBL0001 High Performance Single Board Computer

35

Technical Product Specification

Page 35
Image 35
Intel MPCBL0001 manual Sensor Thresholds for Ipmc Firmware, Sensor Name, Normal, Number, Value