Intel MPCMM0002 manual Physical Bus Number Mapping, Ipmb Signal Physical Bus Number

Models: MPCMM0002

1 93
Download 93 pages 17.99 Kb
Page 63
Image 63

MPCMM0002 CMM—Guidelines for Third Party Chassis Vendors

Table 28.

Physical Bus Number Mapping

 

 

 

 

 

 

 

IPMB Signal

Physical

IPMB Signal

Physical

 

Bus Number

Bus Number

 

 

 

 

 

 

 

 

 

BP_N_SDA_[1]_A

1

BP_N_SDA_[1]_B

22

 

 

 

 

 

 

BP_N_SDA_[2]_A

2

BP_N_SDA_[2]_B

23

 

 

 

 

 

 

BP_N_SDA_[3]_A

3

BP_N_SDA_[3]_B

24

 

 

 

 

 

 

BP_N_SDA_[4]_A

4

BP_N_SDA_[4]_B

25

 

 

 

 

 

 

BP_N_SDA_[5]_A

5

BP_N_SDA_[5]_B

26

 

 

 

 

 

 

BP_N_SDA_[6]_A

6

BP_N_SDA_[6]_B

27

 

 

 

 

 

 

BP_N_SDA_[7]_A

7

BP_N_SDA_[7]_B

28

 

 

 

 

 

 

BP_N_SDA_[8]_A

8

BP_N_SDA_[8]_B

29

 

 

 

 

 

 

BP_N_SDA_[9]_A

9

BP_N_SDA_[9]_B

30

 

 

 

 

 

 

BP_N_SDA_[10]_A

10

BP_N_SDA_[10]_B

31

 

 

 

 

 

 

BP_N_SDA_[11]_A

11

BP_N_SDA_[11]_B

32

 

 

 

 

 

 

BP_N_SDA_[12]_A

12

BP_N_SDA_[12]_B

33

 

 

 

 

 

 

BP_N_SDA_[13]_A

13

BP_N_SDA_[13]_B

34

 

 

 

 

 

 

BP_N_SDA_[14]_A

14

BP_N_SDA_[14]_B

35

 

 

 

 

 

 

BP_N_SDA_[15]_A

15

BP_N_SDA_[5]_B

36

 

 

 

 

 

 

BP_N_SDA_[16]_A

16

BP_N_SDA_[16]_B

37

 

 

 

 

 

 

BP_CF_SDA_A

17

BP_CF_SDA_B

38

 

 

 

 

 

 

BP_SH_SDA_A

18

BP_SH_SDA_B

39

 

 

 

 

 

 

BP_RED_SDA_A

19

BP_RED_SDA_B

40

 

 

 

 

 

 

BP_RP_SDA_A

20

BP_RP_SDA_B

41

 

 

 

 

 

 

BP_SP_SDA_A

21

BP_SP_SDA_B

42

 

 

 

 

 

Among the 42 IPMB buses, two buses, 18 and 39 (signals BP_SH_SDA_A and

BP_SH_SDA_B respectively in Table 28), have a special feature. Each bus is wired to an LTC4300 (IPMB bus isolator) part before making to the backplane. The IPMB bus isolator allows detection of bus hangs. Intel highly recommends using these buses (in a redundant mode) for chassis that use a shared bus topology. Figure 34 shows the radial bus topology. Figure 35 shows the shared bus topology.

IPMB buses BP_RED_SDA_A/ BP_RED_SDA_B (physical bus number 19 and 40) are reserved to be used as a dedicated redundant connection between two CMMs in the chassis.

IPMB buses BP_CF_SDA_A/BP_CF_SDA_B (physical bus number 17 and 38) are intended to be used as a dedicated redundant IPMB buses between CMMs and chassis FRU.

IPMB buses BP_SP_SDA_A/BP_SP_SDA_B & BP_RP_SDA_A/BP_RP_SDA_B are reserved for future use, however they can be configured by chassis vendors as any general purpose IPMB buses in redundant or individual configuration.