Document 
Chapter 17.0, “Agency Information” contains notices from various certifying agencies. Chapter 18.0, “Safety Warnings” lists important safety warnings in various languages.
1.1Acronyms and Terms
| 
 | The following special acronyms and terms are used in this specification: | |
| Table 1. | Acronyms and Terms | |
| 
 | 
 | 
 | 
| 
 | Acronym/Term | Meaning | 
| 
 | 
 | 
 | 
| 
 | Board | Front Board as defined in PICMG 3.0 specification | 
| 
 | 
 | 
 | 
| 
 | CDM | Chassis Data Module | 
| 
 | 
 | 
 | 
| 
 | CFM | Cubic Feet per Minute | 
| 
 | 
 | 
 | 
| 
 | Chassis | Physical structure containing boards, backplane, PEMs, etc,; same as shelf | 
| 
 | 
 | 
 | 
| 
 | CMM | Chassis Management Module | 
| 
 | 
 | 
 | 
| 
 | COM | Common connection [used with relay contacts in Section 9.3, “Telco Alarm | 
| 
 | Connector” on page 48. | |
| 
 | 
 | |
| 
 | 
 | 
 | 
| 
 | Component Side 1 | Primary side of PCB, used for synergy with PICMG 3.0 terminology | 
| 
 | 
 | 
 | 
| 
 | Component Side 2 | Secondary side of PCB | 
| 
 | 
 | 
 | 
| 
 | EMI | Electromagnetic Interference | 
| 
 | 
 | 
 | 
| 
 | ESD | Electrostatic Discharge | 
| 
 | 
 | 
 | 
| 
 | ETSI | European Telecommunications Standards Institute | 
| 
 | 
 | 
 | 
| 
 | Frame | Structure in which chassis is mounted; could be enclosed or open; same as rack | 
| 
 | 
 | 
 | 
| 
 | FRU | Field Replaceable Unit | 
| 
 | 
 | 
 | 
| 
 | I2C | |
| 
 | IPMB | Intelligent Platform Management Bus | 
| 
 | 
 | 
 | 
| 
 | IPMI | Intelligent Platform Management Interface | 
| 
 | 
 | 
 | 
| 
 | LED | Light Emitting Diode | 
| 
 | 
 | 
 | 
| 
 | LFM | Linear Feet per Minute | 
| 
 | 
 | 
 | 
| 
 | MLBF | Mate Last, Break First. Refers to the shortest pin. Used to enable a Hot Swap | 
| 
 | controller to cut or connect power to a board. | |
| 
 | 
 | |
| 
 | 
 | 
 | 
| 
 | NC | No Connect [exception: in Section 9.3, refers to Normally Closed relay contacts] | 
| 
 | 
 | 
 | 
| 
 | NEBS | Network Equipment Building Standards | 
| 
 | 
 | 
 | 
| 
 | NO | Normally Open [for relay contacts in Section 9.3] | 
| 
 | 
 | 
 | 
| 
 | PCB | Printed Circuit Board | 
| 
 | 
 | 
 | 
| 
 | PEM | Power Entry Modules | 
| 
 | 
 | 
 | 
| 
 | PICMG | PCI Industrial Computers Manufacturers Group, sponsor of AdvancedTCA | 
| 
 | specification | |
| 
 | 
 | |
| 
 | 
 | 
 | 
| 
 | Rack | Structure in which chassis is mounted; could be enclosed or open; same as frame | 
| 
 | 
 | 
 | 
| 
 | RTM | Rear Transition Module | 
| 
 | 
 | 
 | 
| 
 | SCap | Super Capacitor | 
| 
 | 
 | 
 | 
| 
 | SEL | System Event Log | 
| 
 | 
 | 
 | 
| 
 | Shelf | See Chassis | 
| 
 | 
 | 
 | 
| 
 | ShMC | Shelf Management Controller | 
| 
 | 
 | 
 | 
| 
 | SSI | Server System Infrastructure | 
| 
 | 
 | 
 | 
| 
 | Intel NetStructure® MPCMM0002 Chassis Management Module | 
| July 2007 | Hardware TPS | 
| Order Number:  | 9 | 