Power Management Setup CBI/CGI Technical Reference
Chassis Plans.6-4
Available options are:
Disabled
1 through 15, in increments of 1 minute
Power Saving Type
The Setup screen displays the system option:
Power Saving Type POS
Available options are:
POS (Power On Suspend)
Sleep
Stop Clock
Deep Sleep
Standby/Suspend Timer Unit
This option specifies the unit of time used for the Standby and Suspend time-out periods.
The Setup screen displays the system option:
Standby/Suspend Timer Unit 4 Min
Available options are:
32 secs
4 msec
4 min
4 sec
Standby Time Out
This option specifies the length of the period of system inactivity when the computer is
in full power-on mode before it is placed in Standby mode. In Standby mode, some
power use is curtailed.
The default for this option depends on the value selected in the Standby/Suspend Timer
Unit option.
The Setup screen displays the system option:
Standby Time Out Disabled
Available options are:
Disabled
32 through 4064, in increments of 32 (if the Standby/Suspend
Timer Unit option is set to 32 secs)
4 through 508, in increments of 4 (if the Standby/Suspend
Timer Unit option is set to 4 msec, 4 min or 4 sec)