B

A

TP02206

Figure 30. Removing Hot-swap Disk Carrier from the Server System

4.Remove the four screws that attach the plastic retention device or the previously installed hard drive to the drive carrier. Two screws are at each side of the retention device or the hard drive. Store the plastic retention device for future use.

B

A

TP02207

Figure 31. Removing Retention Device from Drive Carrier

5.Remove the hard drive from its wrapper and place it on an antistatic surface.

6.Set any jumpers and/or switches on the drive according to the drive manufacturer's instructions.

7.With the drive circuit-side down, position the connector end of the drive so that it is facing the rear of the drive carrier.

8.Align the holes in the drive to the holes in the drive carrier and attach it to the carrier with the screws that were attached to the plastic retention device.

40

Intel® Server System SR1500AL User’s Guide

Page 62
Image 62
Intel SR1500AL manual Removing Hot-swap Disk Carrier from the Server System