BMC Force

Update Mode

2

3

J1D2

 

Disable

Password

2

Enable

Reset

3

 

 

J1D1

2

3

J1D3

Clear

CMOS

TP02080

Jumper Name

Jumper Purpose

 

 

CMOS Clear

If pins 2-3 are jumpered, the CMOS settings will be cleared on the

 

next reset. These pins should be jumpered on 1-2 for normal

 

operation.

 

 

Password Clear

If pins 2-3 are jumpered, administrator and user passwords will be

 

cleared on the next reset. These pins should be jumpered on 1-2 for

 

normal operation.

 

 

BMC Force Update Mode

If pins 2-3 are jumpered, BMC Force Update Mode is enabled.

 

These pins should be jumpered on 1-2 for normal operation.

 

 

 

Figure 5. Recovery Jumpers

Intel® Server System SR1500AL User’s Guide

9

Page 31
Image 31
Intel SR1500AL manual Recovery Jumpers