56 Intel® Server System SR1500AL User’s Guide
9. Install the processor air duct. For instructions, see “Installing the Processor Air
Duct”.
10. Install the server system cover. For instructions, see “Installing the System Cover”.
11. Plug all peripheral devices and the AC power cable(s) into the server.
Installing and Removing the Intel® Remote Management Module and the Intel® RMM NIC

Installing the Intel® RMM and Intel® RMM NIC

1. Observe the safety and ESD precautions at the beginning of this book. See “Safety
Information”.
2. Power down the server and unplug all peripheral devices and the AC power
cable(s).
3. Remove the server system cover. For instructions, see “Removing the System
Cover”.
4. Remove the PCI riser assembly. For instructions, see “Removing the PCI Riser
Assembly”.
5. Squeeze the sides of the Intel® RMM NIC module cover to disengage it from the
server system back panel and remove it. See letter “A” in the figure below.
6. Attach the standoffs to the server board (see letter “B” in the figure below) and
attach the Intel® RMM NIC module to the server board (see letter “C” in the figure
below).
7. Insert the standoff into the hole labeled TH4 on the Intel® RMM board (see letter
“D” in the figure below). The standoff installs on the bottom side of the Intel®
RMM board.
8. Attach the Intel® RMM board to the server board connector and snap the standoff
into the matching hole on the server board.
Figure 46. Installing the Intel® RMM and the Intel® RMM NIC Module to the
Server System
A
B
D
E
C
AF000747