23
CONTROLS, INDICATORS AND CONNECTORS
5Audio sampling frequency in-
dication
32 K : Indicated when the AUDIO MODE item on the AUDIO/MIC menu screen is set to 32 K. (Audio is
recorded with 12-bit, 32 kHz sampling.)
48 K : Indicated when the AUDIO MODE item on the AUDIO/MIC menu screen is set to 48 K. (Audio is
recorded with 16-bit, 48 kHz sampling.)
XSeepage 70.
6Audio level meter indication Displays the CH-1, CH-2 audio level meters.
Whether or not to display this item is set with the AUDIO item on the LCD/VF [2/3] menu.
XSeepage 72.
7Standard audio level indication The level at which audio is recorded on the tape is indicated by “O”.
–20 dB, –12 dB
XSee“AUDIO REF.LEVEL ” on page 70.
8Iris indicator display M: Iris set higher than normal
b: Iris set to normal
N: Iris set lower than normal
9Iris F-value indication Indicates the F-number of the connected lens.
OPEN, F2, F2.8, F4, F5.6, F8, F11, F16, CLOSE
It is not displayed when the lens is removed. For some lenses, no display appears.
The indication can be switched ON/OFF with the F.NO/IRIS IND. item on the LCD/VF [1/3] menu screen.
XSeepage 71.
0Filter position indication Indicates the current filter position.
No display: FILTER OFF
ND1: FILTER ND1 (1/4ND)
ND2: FILTER ND2 (1/16ND)
The indication can be switched ON/OFF with the FILTER item on the LCD/VF [1/3] menu screen.
XSeepage 71.
No. Item Contents
–20 dB –12 dB
OO
CH-1 OOOOO•••+
CH-2 OOOOO•••+
e_hd100.book Page 23 Thursday, July 14, 2005 5:28 PM