USING EXTERNAL COMPONENTS

Backup Recording

1.

IEEE1394 switch

HDV

VIDEO/Y

 

IEEE 1394

 

 

DV

 

 

 

PB

 

OUTPUT

PR

 

LINE

IEEE1394

 

INPUTDC

Backup unit

 

 

Master unit

 

 

GY-HD100

 

 

 

Signal flow

IEEE1394 cable

CAUTION

Set the IEEE1394 switch on both devices to either HDV or DV.

Start recording after making sure that both devices are properly connected.

OTHERS [2/2] menu screen

„Backup Recording of the GY-HD100’s Camera Image and Sound Through the

IEEE1394 Connector

The GY-HD100’s camera image and sound can be recorded for backup on another component that is equipped with IEEE1394 connector.

„Connections

Use the GY-HD100 as the master unit.

Connect the master unit and the backup unit with a IEEE1394 cable.

„Settings

„Master unit (GY-HD100)

1.Set the IEEE1394 switch on left side of the GY-HD100.

DV

: When backup in DV format

HDV

: When backup in HDV format

2.Place in Camera mode.

3.Set the 1394 REC TRIGGER item on the OTHERS [2/2] menu screen. X See page 78.

„Backup unit

• Place in HDV/DV signal input mode.

* Depending on the used component, it may be necessary to set “REMOTE SELECT”.

When BR-HD50 is used, set the Backup Recording func- tion to OFF.

Insert the tape and set to STOP or REC PAUSE status.

„Operation

Start and stop of recording on the backup unit takes place in accordance with the operation of the REC/VTR trigger button on the master unit.

(Depending on the GY-HD100 or the backup unit, the image, audio, and/or time code may deviate from what they should be at the points where the recording is started or stopped.)

MEMO

When the backup recording is started, the “TRIGGER TO DV” or “TRIGGER TO HDV” indication is shown on the LCD or in the viewfinder for approx. 3 seconds.

When the Series Recording function of BR-HD50 is used, the GY-HD100’s 1394 REC TRIGGER item should be set to OFF.

If the backup device is equipped with a feature to record time codes input from the IEEE1394 connector (TC DUPLICATE feature), time code data the same as on the master side can be recorded.

When using BR-HD50 as a backup device and switching GY-HD100 from the playback mode to the record mode, noise will be noticed on the monitor output screen of BR- HD50 (backup will be correctly recorded).