TV MEASUREMENT

CHANNEL DISPLAY AND ENTRY

To measure the level of a reception signal, you must first enter the desired channel.

The following channels can be set:

Band I/III

CH 01 to CH 12 in 7 MHz raster

Band IV/V

CH 21 to CH 69 in 8 MHz raster

Special channel

S 01 to S 20 in 7 MHz raster

Special channel

S 21 to S 41 in 8 MHz raster

These details refer to the default Standard B/G only. For information on the other standards please see the technical appendix.

COMMAND OVERVIEW FOR TV CHANNEL ENTRY

or

or

Example

Note

 

Switch to desired TV reception

...

Enter channel

Confirm entry

... Enter channel (automatic

 

confirmation)

 

Switch to special channel

and

Change channels in intervals

To enter channel S 28:

Press .

LC display:

Special channel: S 28

Level: 62.5 dBµV

Operating mode: Analogue cable TV (A=analogue)

Ensure that the correct standard has been set. The default setting is Standard B/G.

FREQUENCY DISPLAY AND ENTRY

To measure the level of a reception signal, you must first enter the desired video carrier frequency.

The frequency can be entered from 47 MHz to 862 MHz in 50 kHz intervals.