Kathrein MSK 125 manual Command Overview for Data Byte

Models: MSK 125

1 80
Download 80 pages 20.69 Kb
Page 30
Image 30

SAT

39

Write N1

Set port group 1

1

3A

Write N2

Expansion option

1

3B

Write N3

Expansion option

1

40

Read A0

Read analogue value A0

-

41

Read A1

Read analogue value A1

-

48

Write A0

Set analogue value A0

1

49

Write A1

Set analogue value A1

1

4F

Write A7

Set analogue value A7

1

50

LO string

Read current frequency

-

51

LO now

Read current frequency (table entry number)

-

52

LO Lo

Read Lo frequency (table entry number)

-

53

LO Hi

Read Hi frequency (table entry number)

-

58

Write Freq

Write channel frequency

2 or 3

59

Ch.No.

Set selected channel number (receiver)

2

60

Halt

Stop positioner

-

61

Go E

Move positioner eastward

-

62

Go W

Move positioner westward

-

64

P Status

Read positioner status register

-

65

Read Pos

Read positioner counter

-

6C

Goto

Move positioner motor to “Counter value”, Hi, Lo

2

6D

Write Pos

Set positioner counter, Hi, Lo

2

COMMAND OVERVIEW FOR DATA BYTE

An appropriate data byte must only be sent id the command byte requires data bytes. This can be seen in the above command byte table. For more information on which data byte to send to which command byte please refer to the specification of the device used.

Orbit

Polarisation

Switch Position

 

Switch Position

Data Byte

position

H/V

Low Band

 

 

 

 

 

V

Lo

F0

1

V

Hi

F1

H

Lo

F2

 

 

H

Hi

F3

 

V

Lo

F4

2

V

Hi

F5

H

Lo

F6

 

 

H

Hi

F7

 

V

Lo

F8

3

V

Hi

F9

H

Lo

FA

 

 

H

Hi

FB

 

V

Lo

FC

4

V

Hi

FD

H

Lo

FE

 

 

H

Hi

FF

30

Page 30
Image 30
Kathrein MSK 125 manual Command Overview for Data Byte, Orbit Polarisation Switch Position Data Byte Low Band