BATTERY OPERATION

Note

GETTING STARTED

Before operating the device for the first time remove the T 8.0 A fuse from the packaging and place it in the fuse holder.

This fuse prevents the device from being switched on accidentally during transportation.

After the fuse has been inserted the charging status display does not function properly until the battery has been fully discharged once.

Battery operation is only possible if the battery is charged sufficiently. Otherwise the MSK 125 cannot be switched on.

Once the battery has fully discharged it must be recharged immediately to avoid damage to the battery.

Charging starts automatically after the device has been connected to the mains. The battery cannot overcharge thanks to a protection switch.

Battery operation is signalled by a red LED next to the button.

The battery capacity is 6.45 Ah.

Press the button to check the charging status of the lithium- ion battery.

The LC display indicates the following values:

LNB or remote feeding voltage: 14.0 V

LNB or remote feeding amperage: 255 mA

22 kHz switch on

Battery charging status: 80 %

Bar graph (8 x 10 %)

Press the button again to exit this operating mode.

17

Page 17
Image 17
Kathrein MSK 125 manual Battery Operation