Kodak A-61555 manual Udds Calibration

Models: A-61555

1 108
Download 108 pages 45.9 Kb
Page 43
Image 43

UDDS Calibration

UDDS calibration is used to calibrate the ultrasonic document detection system for multi-feeds. UDDS calibration is rarely needed. This calibration should only be performed if there is a feeding or multi-feed detection issue.

1.Touch Calibrate. The Calibration screen will be displayed.

2.Touch UDDS Calibration to display the UDDS Calibration screen.

3.You will be prompted to place a 20 lb. or 75 g/m2 bond sheet of paper in the input elevator. Do not use the calibration target.

4.Touch OK. The calibration results will be displayed.

5.When finished, touch End Job to return to the Idle screen.

3-26

A-61555 April 2009

Page 43
Image 43
Kodak A-61555 manual Udds Calibration