Kodak A-61555 manual Replacing the pre, Separation pad, Replacing the imaging, Guides

Models: A-61555

1 108
Download 108 pages 45.9 Kb
Page 92
Image 92

Replacing the pre-

Change the pre-separation pad when the frequency of multi-fed

separation pad

documents increases.

 

1.

Open the pod.

 

2.

Remove the pre-separation pad by lifting the pad up and out of

 

 

position.

 

3.

Install the new pre-separation pad. Be sure it snaps into place.

 

4.

Close the pod.

Replacing the imaging

The imaging guides should be replaced when they are heavily

guides

scratched and defects show in the image.

 

NOTE: Handle the imaging guides carefully so as to not put fingerprints

 

 

on the guides.

 

1.

Open the pod.

 

2.

Turn the screw on each end of the lower imaging guide to remove it

 

 

from its position.

3.Install the new imaging guide and turn the screws to secure the imaging guide.

4.Repeat Steps 2 and 3 to replace the upper imaging guide.

5.Close the pod.

5-20

A-61555 April 2009

Page 92
Image 92
Kodak A-61555 manual Replacing the pre, Separation pad, Replacing the imaging, Guides