Lantronix LX6 manual Commands and Levels, Accept tunnel-accept1 level commands

Models: LX6

1 87
Download 87 pages 781 b
Page 39
Image 39

5: Commands and Levels

host 10 (tunnel-connect-host:1:10)

host 11 (tunnel-connect-host:1:11)

host 12 (tunnel-connect-host:1:12)

host 13 (tunnel-connect-host:1:13)

host 14 (tunnel-connect-host:1:14)

host 15 (tunnel-connect-host:1:15)

host 16 (tunnel-connect-host:1:16)

disconnect (tunnel-disconnect:1)

modem (tunnel-modem:1)

packing (tunnel-packing:1)

serial (tunnel-serial:1)

xml (xml)

 

Table 5-1 Commands and Levels

 

 

accept (tunnel-accept:1) level commands

accept mode always

 

Enables the tunneling server to always accept tunneling

 

 

connections.

accept mode any character

 

Enables the tunneling server to accept tunneling connec-

 

 

tions only when a

 

 

character is received through the corresponding line (seri-

 

 

al port).

accept mode disable

 

Disables accept mode tunneling.

accept mode modem control asserted

 

Enables the tunneling server to accept tunneling connec-

 

 

tions when the modem

 

 

control pin is asserted.

accept mode modem emulation

 

Enables modem emulation for accept mode tunneling.

accept mode start character

 

Enables accept mode tunneling when the configured start

 

 

character

 

 

is received on the line.

aes decrypt key <hexadecimal>

 

Sets the accept tunnel AES decrypt key with up to 16

 

 

bytes.

 

 

Each byte is represented by two adjacent hex digits.

 

 

Bytes may run together or be separated by optional punc-

 

 

tuation:

 

 

123ABC "12 3A BC" 12,3A,BC 12.3a.bc 12:3a:bc

 

 

Note that quotes must enclose the value if it contains

 

 

spaces.

aes decrypt key text <text>

 

Sets the accept tunnel AES decrypt key with up to 16

 

 

bytes.

 

 

Each byte is represented by a single character.

 

 

Note that quotes must enclose the value if it contains

 

 

spaces.

aes encrypt key <hexadecimal>

 

Sets the accept tunnel AES encrypt key with up to 16

 

 

bytes.

 

 

Each byte is represented by two adjacent hex digits.

 

 

Bytes may run together or be separated by optional punc-

 

 

tuation:

 

 

123ABC "12 3A BC" 12,3A,BC 12.3a.bc 12:3a:bc

 

 

Note that quotes must enclose the value if it contains

 

 

spaces.

aes encrypt key text <text>

 

Sets the accept tunnel AES encrypt key with up to 16

 

 

bytes.

XPort® Pro Lx6 Embedded Device Server Command Reference

39

Page 39
Image 39
Lantronix LX6 manual Commands and Levels, Accept tunnel-accept1 level commands