4: Configuration Using XML

Group Name

Group Item

Value Name

Value Options

Additional

(continued)

 

 

 

Information

line

name

 

 

 

(Attribute of

 

 

 

 

interface

 

rs232, rs485 half-

Default:

“instance” is a

 

 

duplex, rs485 full-

 

number.)

 

 

duplex, usb-cdc-acm

 

 

 

 

 

 

termination

 

enable, disable

Default: disable

 

 

 

 

 

 

state

 

enable, disable

Default: depends on

 

 

 

 

instance

 

 

 

 

 

 

protocol

 

none, tunnel

Default:

 

 

 

 

 

 

baud rate

 

 

Default: 9600 bits per

 

 

 

 

second

 

 

 

 

 

 

parity

 

even, none, odd

Default: none

 

 

 

 

 

 

data bits

 

7, 8

Default: 8

 

 

 

 

 

 

stop bits

 

1, 2

Default: 1

 

 

 

 

 

 

flow control

 

none, hardware,

Default: none

 

 

 

software

 

 

 

 

 

 

 

xon char

 

 

Accepts a control

 

 

 

 

character, for example,

 

 

 

 

<control>A

 

 

 

 

represents control-A

 

 

 

 

Default: <control>Q

 

 

 

 

 

 

xoff char

 

 

Accepts a control

 

 

 

 

character, for example,

 

 

 

 

<control>A

 

 

 

 

represents control-A

 

 

 

 

Default: <control>S

 

 

 

 

 

 

gap timer

 

<None>, ...

Default: <None>

 

 

 

 

 

 

threshold

 

 

Default: 56 bytes

 

 

 

 

 