Lantronix LX6 manual Packing tunnel-packing1 level commands, Timeout milliseconds

Models: LX6

1 87
Download 87 pages 781 b
Page 81
Image 81

 

 

5: Commands and Levels

 

 

 

response type text

Uses text type responses.

show

Displays the current configuration.

show history

Displays the last 20 commands entered during the current

 

 

CLI session.

show status

Displays tunnel modem status.

verbose response disable

Does not send Modem Response Codes.

verbose response enable

Sends Modem Response Codes out on the Serial Line.

write

Stores the current configuration in permanent memory.

packing (tunnel-packing:1) level commands

 

clrscrn

Clears the screen.

default packing mode

Sets to default packing mode, which is "Disable"

default send character

Removes the send character for packing mode.

default threshold

Restores the default threshold.

default timeout

Restores the default packing mode timeout.

exit

Returns to the tunnel level.

no trailing character

Removes the trailing character for packing mode.

packing mode disable

Disables packing. Data is sent to the network when re-

 

 

ceived.

packing mode send character

Sets packing mode to accumulate data and transmit it

 

 

upon receiving the

 

 

configured send character on the line (serial port).

packing mode timeout

Sets packing mode to accumulate data and transmit it

 

 

after a specified

 

 

amount of time (timeout).

send character <control>

Sets the send character for packing mode.

 

 

The character may be input as text, control, decimal, or

 

 

hex.

 

 

A control character has the form <control>C.

 

 

A decimal value character has the form \99.

 

 

A hex value character has the form 0xFF.

show

Displays the current configuration.

show history

Displays the last 20 commands entered during the current

 

 

CLI session.

threshold <bytes>

Sets the threshold (byte count). If the queued data reach-

 

 

es this threshold

 

 

then the data will be sent.

 

 

<bytes> = number of bytes in the threshold.

timeout <milliseconds>

Sets the timeout value for packing mode in milliseconds.

 

 

<milliseconds> = timeout value, in milliseconds.

trailing character <control>

Sets the trailing character for packing mode.

 

 

The character may be input as text, control, decimal, or

 

 

hex.

 

 

A control character has the form <control>C.

 

 

A decimal value character has the form \99.

 

 

A hex value character has the form 0xFF.

write

Stores the current configuration in permanent memory.

password (tunnel-accept-password:1) level commands

 

clrscrn

 

Clears the screen.

exit

 

Exits to the next higher level.

no password

 

Removes the password so connections will be accepted

XPort® Pro Lx6 Embedded Device Server Command Reference

81

Page 81
Image 81
Lantronix LX6 manual Packing tunnel-packing1 level commands, Timeout milliseconds