6:Line and Tunnel Settings

The XPort Pro Lx6 embedded device server contains one line using a standard RS232/RS485 serial port. This line may be configured to operate in the following modes:

RS232

RS485 Full Duplex (also compatible with RS-422)

RS485 Half Duplex, with and without termination impedance

All serial settings such as Baud Rate, Parity, Data Bits, etc, apply to these lines.

Line Settings

The Line Settings allow configuration of the serial lines (ports).

Some settings may be specific to only certain lines. Such settings are noted below.

 

Table 6-1 Line Configuration Settings

 

 

 

 

Line Settings

Description

 

Name

Enter a name or short description for the line, if desired. By default, there is

 

no name specified. A name that contains white space must be quoted.

 

 

 

Interface

Set the interface type for the Line. The default is RS232 for Line 1.

 

 

Choices are:

 

 

RS232

 

 

RS485 Full-Duplex

 

 

RS485 Half-Duplex

 

 

 

Termination

Select to Enable or Disable Line Termination. The default is Disable.

 

Note: This setting is only relevant for Line 1 with Interface type RS485 Half-

 

Duplex.

 

 

 

State

Select to Enable or Disable the operational state of the Line. The default is

 

Enable.

 

 

 

Protocol

Set the operational protocol for the Line. The default is Tunnel. Choices are:

 

None

 

 

Tunnel = Serial-Network tunneling protocol.

 

 

 

 

Baud Rate

Set the Baud Rate (speed) of the Line. The default is 9600.

 

 

Any set speed between 300 and 921600 may be selected: 300, 600, 1200,

 

2400, 4800, 9600, 19200, 38400, 57600, 115200, 230400, 921600.

When

 

selecting a Custom baud rate, you may manually enter any value between

 

300 and 921600.

 

 

Note: Custom baud rates are not supported when a line is configured for

 

Command Mode.

 

 

 

 

Parity

Set the Parity of the Line. The default is None.

 

 

 

 

Data Bits

Set the number of data bits for the Line. The default is 8.

 

 

 

 

Stop Bits

Set the number of stop bits for the Line. The default is 1.

 

 

 

 

Flow Control

Set the flow control for the Line. The default is None.

 

 

 

 

XPort® Pro Lx6 Embedded Device Server User Guide

27