6: Line and Tunnel Settings

 

 

 

 

Tunnel Connect Mode

Description

 

Settings (continued)

 

 

Email on Disconnect

Select an email profile number to which an email notification will be sent upon

 

 

the disconnection of an accept mode tunnel.

 

 

 

 

CP Output

Enter the CP Output Group whose value should change when a connection is

 

 

established and dropped. Connection Value specifies the value to set the CP

 

 

Group to when a connection is established. Disconnection Value specifies the

 

 

value to set the CP Group to when the connection is closed. To display the

 

 

“Connection Value” and “Disconnection Value”, first enter a “CP Output Group”,

 

 

then click outside that field.

 

 

 

To Configure Tunnel Connect Mode Settings

Using Web Manager

To configure the Connect Mode for a specific tunnel, click Tunnel in the menu and select Tunnel 1 -> Connect Mode.

Using the CLI

To enter the Tunnel 1 Connect Mode command level: enable -> tunnel 1 -> connect

Using XML

Include in your file: <configgroup name="tunnel connect" instance="1">

Disconnect Mode

Specifies the optional conditions for disconnecting any Accept Mode or Connect Mode connection that may be established. If any of these conditions are selected but do not occur and the network disconnects to the device, a Connect Mode connection will attempt to reconnect. However, if none of these conditions are selected, a closure from the network is taken as a disconnect.

 

Table 6-7 Tunnel Disconnect Mode Settings

 

 

Tunnel Disconnect

Description

Mode Settings

 

Stop Character

Enter the Stop Character which when received on the Serial Line, disconnects the

 

tunnel. The Stop Character may be designated as a single printable character or

 

as a control character. Control characters may be input in any of the following

 

forms: <control>J or 0xA(hexadercimal) or \10 (decimal). Disable the Stop

 

Character by blanking the field to set it to <None>.

 

 

Modem Control

Set whether Modem Control enables disconnect when the Modem Control pin is not

 

asserted on the Serial Line. Choices are:

 

Enabled

 

Disabled (default)

 

 

Timeout

Enter the number of milliseconds a tunnel may be idle before disconnection. The

 

value of zero disables the idle timeout.

 

 

Flush Serial Data

Set whether to flush the Serial Line when the Tunnel is disconnected. Choices are:

 

Enabled

 

Disabled (default)

 

 

XPort® Pro Lx6 Embedded Device Server User Guide

35