Table 4-17: PostScript Emulation Device Parameters (Continued)

Key

Type

Definition

 

PCLSmartSwitch

boolean

Supported values are:

 

 

True

PCL SmartSwitch is On.

 

 

False

PCL SmartSwitch is Off.

 

 

For more information, see “Using SmartSwitch” on page 2-1.

 

 

 

PortLocation

string

(Read-only) Designates the physical location of the port related to the parameter set.

 

 

Supported values are:

 

 

Standard Port

 

 

Option Slot 1

 

 

Option Slot 2

 

 

Option Slot 3

 

 

 

PSSmartSwitch

boolean

Supported values are:

 

 

True

PS SmartSwitch is On.

 

 

False

PS SmartSwitch is Off.

 

 

For more information, see “Using SmartSwitch” on page 4-1.

 

 

 

Type

name

(Read-only) Always returns the value of /Communications.

 

 

 

 

Device Parameters for the Communication Device %EtherTalk%, %EtherTalkA%, %EtherTalkB%, %EtherTalkC%, %EtherTalkD%

(%EtherTalk_NV% and %EtherTalk_Pending% contain the same parameters)

DelayedOutputClose

boolean

Selects how the printer manages the port at the end of each print job. Supported values are:

 

 

True

An end-of-file message is not sent until the current job and all preceding jobs

 

 

 

finish printing.

 

 

False

An end-of-file message is sent as soon as a job finishes executing in the

 

 

 

interpreter, whether or not that job has finished printing.

 

 

This value is set independently for each port.

 

 

 

 

Enabled

boolean

(Read-only)

 

 

 

Supported values are:

 

 

True

 

 

 

False

 

 

 

 

EthernetAddress

string

(Read only) The Ethernet address of the Ethernet internal print server.

 

 

Legal value: Any string of 17 or fewer non-null characters.

 

 

 

EtherTalkType

string

The “type” of the EtherTalk interface entity name. This parameter also sets the

 

 

LocalTalkType parameter to the same value. The new value is returned by the

 

 

appletalktype compatibility operator.

 

 

Legal value: Any string of 32 or fewer non-null characters. Default value is LaserWriter.

 

 

Note: Setting this variable does not affect the value for other physical internal print servers.

 

 

The statusdict string appletalktype is correct for the current job port.

 

 

 

EtherTalkZone

string

The “zone” of the EtherTalk interface entity name.

 

 

EtherTalkZone is read/write only to RAM. There is no NVRAM variable for EtherTalkZone.

 

 

Legal value: Any string of 32 or fewer non-null characters.

 

 

 

 