Lightwave Communications 3200 user manual Connecting Equipment to the ConsoleServer, Terminal Card

Models: 3200

1 88
Download 88 pages 3.07 Kb
Page 14
Image 14

5.0Connecting Equipment to the ConsoleServer 3200

When connecting devices to the ConsoleServer 3200, be sure to use Lightwave Communications cables and adapters to ensure the proper transmission of data signals. If a device has an RJ45 serial port, use the manufacturer's cable included with the equipment to convert the RJ45 serial connector to a DB9 or DB25 connector, and then use a Lightwave Communications adapter to convert back to RJ45 to attach to the device port. Directly connecting the RJ45 port on the ConsoleServer 3200 to the RJ45 port on a third-party device will not allow for the proper transmission of data signals.

ConsoleServer 3200 serial port default settings

Port Type

Baud Rate

Data Bits

Parity

Stop Bits

Port Configuration

Terminal

38400

8

None

1

DCE

Device

9600

8

None

1

DCE

See Appendix A for further details on connectors and pinouts.

5.1Terminal Card

Terminal Card typical adapters and port configuration:

System Type

Adapter Part Number

Port Configuration

Wyse 50 / 60

200.0066

DCE

DEC VT330, PC (25pin)

200.0067

DCE

PC (9pin)

200.0070

DCE

Materials:

ConsoleServer 3200 terminal port

terminal or computer with RS-232 serial port

RJ45-terminated Cat 5 cable (standard LAN cable)

Lightwave adapter for terminal serial port

1.Attach the Lightwave adapter to the terminal or computer serial port.

2.Connect the Cat 5 cable to the adapter. Connect the other end to the ConsoleServer 3200 terminal port.

3.Turn on the terminal or start the computer’s communication program. Make sure that the communication parameters of the terminal or computer match those of the terminal port.

10

Page 14
Image 14
Lightwave Communications Connecting Equipment to the ConsoleServer, ConsoleServer 3200 serial port default settings