4.0Installation Instructions

4.1Items in the Shipping Container

a)ConsoleServer 3200 user manual

b)User and Sys Admin Quick Reference Cards

c)AC power cord

d)Cable kit part number 200.0135 (four rubber feet included)

e)ConsoleServer 3200 chassis with installed cards

Additional adapters and cables may also be included in the shipping container if ordered. Large cable and adapter orders are usually shipped in separate containers.

4.1Rack/Desktop Installation

The ConsoleServer 3200 is shipped with 19-inch rack mount 'ears' attached for installation in an EIA standard rack. If the unit is to be used in a desktop environment, the 'ears' may be removed and four small rubber feet may be installed on the bottom of the unit to prevent scratching the desktop and allow airflow through the unit. Alternate sizes of rack mount ‘ears’ are also available.

When mounting the ConsoleServer 3200 in a rack, be sure to allow sufficient space behind the unit for cables and adapters.

4.3ConsoleServer 3200 Location and Cooling

The ConsoleServer 3200 will operate in a normal equipment room environment without any problems. The fan located on the power supply module provides airflow for the power supplies, while the majority of cooling relies on convection currents. It is therefore necessary to keep the bottom and top of the unit free from obstruction. Provisions for adequate ventilation should be made if the ConsoleServer 3200 is mounted in an enclosed rack.

The ConsoleServer 3200 generates 34.1 BTU/hr under normal operation. Be sure that the cooling plant for the machine environment can accommodate the additional heat load.

4.4Power Requirements

The ConsoleServer 3200 may operate off AC or DC power, depending on the installed power supply module. The power supply module may be removed and exchanged to allow a different power source (AC or DC).

The AC power module is an auto-switching power supply, operating on 110/220 VAC at 50/60 Hz, and draws approximately 1 A at 110 VAC. An AC power cord is included with

7

Page 11
Image 11
Lightwave Communications 3200 Installation Instructions Items in the Shipping Container, Rack/Desktop Installation