ROBOTIC INTERFACE

ting and clearing the miscellaneous output #4.

 

 

4.12 TOUCH SENSE COMMAND

 

4.4

ARC DETECT

The touch sense command is generated by active low

The arc detect signal is generated from the voltage and

welding output 3 (WDO3). The signal is then inverted

current signals on the control board. The arc detect cir-

and isolated from the robot ground with an output

cuit is calibrated to detect a minimum arc of 15V and

made to conduct 24VAC. The 24VAC connection is the

30A. The signal is isolated from the control ground and

wire feeder 2 trigger.

 

tied to the robot controller welding input 2 (WDI2).

4.13 WIRE+ & WIRE-

 

 

 

 

4.5

GAS FAULT

These two signals work together to cold inch the wire

This signal is not connected to anything on the inter-

at ±80IPM. The forward wire inch command is gener-

face board. The signal (WDI3) is simply re-routed from

ated by active low welding output 4 (WDO4).

The

the robot connector (P82) to the miscellaneous con-

reverse wire inch command is generated by active low

nector (P84). A gas fault is generated when this signal

welding output 5 (WDO5). When either of the two sig-

is tied to the robot ground.

nals is received an isolated inch command is generat-

 

 

ed and tied to the interface wire inching input. At the

4.6

WATER FAULT

same time the motor drive relays switch to the correct

The water fault signal is generated by an active high

direction. The default direction for the motor

drive

(w/low water pressure reading) signal on the display

relays is forward, if both the signals are low at the same

board. The signal is then isolated from the display

time then the motor drive relays are set for reverse. No

ground, inverted, and tied to the robot controller weld-

damage will be caused by driving both signals low at

ing input 5 (WDI5).

the same time.

 

4.7

POWER FAULT

4.14 DUAL PROCEDURE SWITCH COMMAND

 

The power fault signal is generated by checking the

The dual procedure switch command is generated by

12.8V supply on the interface board. If the supply volt-

active low welding output 7 (WDO7). The signal is then

age on the interface board drops below 11.2V then a

isolated from the robot ground and tied to the interface

power fault signal is generated. The signal is then iso-

dual procedure input.

 

lated from the control ground and tied to the robot con-

 

 

troller welding input 6 (WDI6).

4.15 WIRE STICK DETECT

 

 

 

The wire stick detect signal is generated by a voltage

4.8

VOLTAGE FEEDBACK

check across the output studs. The robot controller

The arc voltage feedback signal is generated on the

samples this signal a predetermined time after the Arc

control board. The interface board then filters, multi-

Enable signal changes from enabled to disabled. The

plies by 2, and isolates the signal from the control

signal is then isolated from the control ground and tied

ground. The signal is then tied to the robot controller

to the robot controller wire stick detect inputs (WDI+ &

analog input 1 (ADCH1). A voltage feedback signal of

WDI-).

 

7.62V is equal to an arc voltage of 80V.

 

 

4.9

CURRENT FEEDBACK

 

 

The arc current feedback signal is generated on the control board. The interface board then filters, multi- plies by 4, and isolates the signal from the control ground. The signal is then tied to the robot controller analog input 2 (ADCH2). A current feedback signal of 8.32V is equal to an arc current of 750A.

4.10 WELD START

The weld start command is generated by active low welding output 1 (WDO1). The signal is then isolated from the robot ground, inverted, and tied to the inter- face trigger input.

4.11 GAS START

The gas start command is generated by active low welding output 2 (WDO2). The signal is then isolated from the robot ground and tied to the gas solenoid dri- ver.

POWER WAVE 450