WT Firmware Download Error CodesTable 4-2. WT Download Error Codes NOTE:

DO NOT USE THE disable wt-upgrade COMMAND.

WT Firmware Download Error Codes

The following table provides a list of error codes related to WT firmware download for the 9601 WT and 9630 Series WT. A low severity error code indicates that the WT will automatically restart the firmware download process after a short delay. A high severity error code terminates the firmware download process; in such a case, the user may have to intervene to restart the firmware download process.

Error CodeSeverity NOTE:

All errors starting with “89” originate from the RC. All other errors originate from either the 9601 WT or 9630 Series WT.

Table 4-2. WT Download Error Codes

Error Code

Severity

Description/Recommendation

 

 

 

0x01

Low

Checksum in the received message does not

 

 

match the calculated checksum of the message.

 

 

For the 9601 WT, restart the download process.

 

 

For the 9630 Series WT, the download

 

 

automatically restarts; therefore, no user

 

 

intervention is required.

 

 

 

0x02

Low

WT received an unknown message from the RC.

 

 

For the 9601 WT, restart the download process.

 

 

For the 9630 Series WT, the download

 

 

automatically restarts; therefore, no user

 

 

intervention is required.

 

 

 

0x8b

Low

WT timed out waiting for the protocol message

 

 

from the RC.

 

 

This error code is not supported for the 9601 WT.

 

 

For the 9630 Series WT, the download

 

 

automatically restarts; therefore, no user

 

 

intervention is required.

 

 

 

0x81

Low

Illegal boot code state in the download process.

 

 

For the 9601 WT, restart the download process.

 

 

For the 9630 Series WT, the download

 

 

automatically restarts; therefore, no user

 

 

intervention is required.

 

 

 