Procedure: WT Firmware Download

DWBS Testing

1.Contact the Initialization and Administration System (INADS) center for the appropriate firmware download.

2.Perform a firmware upgrade for the appropriate component(s) by following the directions in the next section (for the WT) or in the DWBS Maintenance document (for the other DWBS components).

Procedure: WT Firmware Download

and Connection

The firmware for the 9601 or 9630 Series WT is updated via the download cable connected to the TN789 RC circuit pack that is administered as a download server. For the 9601 WT, a 9600 baud RS232 connection is used; for the 9630 Series WT, a 38400 baud RS232 connection is used. The download cable must be within 50 feet of the RC circuit pack. For longer distances, range-extension devices are required.

Determining if a Firmware Download is

Required

The following procedure is required for all new, existing, or replacement WTs.

1.From the DEFINITY ECS management terminal (MT), enter the status wt-upgradecommand (for firmware that is stored in the RC). This command brings up the Status of Wireless Terminal Firmware Upgrade form. An example of the form appears as follows:

4-2Issue 5 June 1999