Lucent Technologies 555-232-102 manual 2. WT Download Error Codes continued, Severity

Models: 555-232-102

1 132
Download 132 pages 48.73 Kb
Page 107
Image 107
Table 4-2. WT Download Error Codes (continued)

Procedure: WT Firmware Download and Connection

Table 4-2. WT Download Error Codes (continued)

Error Code

Severity

Description/Recommendation

 

 

 

0x82

Low

WT timed out waiting for the program data from

 

 

the RC.

 

 

For the 9601 WT, restart the download process.

 

 

For the 9630 Series WT, the download

 

 

automatically restarts; therefore, no user

 

 

intervention is required.

 

 

 

0x83

High

Download cable is not connected.

 

 

Connect the download cable between the RC

 

 

and the WT, and restart the download process. If

 

 

the cable is connected and the error continues to

 

 

occur, use another download cable.

 

 

 

0x84

High

Error while programming flash device.

 

 

Restart the download process. If the error

 

 

continues to occur, try a fully charged battery.

 

 

 

0x85XX

High

Flash memory erase error; reason XX.

 

 

Restart the download process. If the error

 

 

continues to occur, try a fully charged battery.

 

 

 

0x86

Low

WT timed out waiting for RC “info” message.

 

 

For the 9601 WT, restart the download process.

 

 

For the 9630 Series WT, the download

 

 

automatically restarts; therefore, no user

 

 

intervention is required.

 

 

 

0x87

High

RC wants to communicate at a bad baud rate.

 

 

Restart the download process.

 

 

 

0x88

High

RC wants to send a file in an unsupported

 

 

format.

 

 

Restart the download process.

 

 

 

0x891

High

The connected RC circuit pack is not enabled or

 

 

assigned as a server and is therefore disabled

 

 

from allowing WT upgrades.

 

 

Check the Feature-Related System Parameters

 

 

form at the bottom of page 2 for the RC circuit

 

 

pack. If the circuit pack is not listed, issue the

 

 

change system feature command and add it to

 

 

the list. Then issue the enable wt-upgrade

 

 

[PPCSS] command.

 

 

 

Issue 5 June 1999 4-13

Page 107
Image 107
Lucent Technologies 555-232-102 manual 2. WT Download Error Codes continued, change system feature command and add it to