Procedure: Verifying Operative

DWBS Testing

c.Press the More soft key.

3.Upon completing your walk-through, if you have encountered any problems, refer to the DWBS Maintenance document for further investigation.

Procedure: Verifying Operative

Cell IDs

This procedure verifies that all the cells in the wireless configuration are “up” and providing coverage.

Manual backgroundManual background NOTE:

Cell IDs for the 9630 Series WTs update dynamically. Therefore, the following procedure is not required for 9630 Series WTs.

1.Move the 9601 WT battery away from its set position slightly; then reinsert it.

2.For a 9601 WT, using the installation map as a guide, step into the first cell to be checked, and position yourself close to the CAU (or to the WFB, if no CAUs are present) for the particular cell. Obtain the cell ID by executing the following key sequence on the 9601 WT:

a.Press

b.Press

Menu

Next

.

.

c. Press the Info Manual background soft key.

d. Press Next to display the cell ID.

3.Confirm that the cell ID is displayed. If the cell ID is displayed, repeat Step 1 for all the cells in the configuration. If there is no cell ID displayed, use the following table:

If...

Then...

 

 

Unit is a CAU

Go to Step 3

 

 

Unit is a WFB

Go to Step 4

 

 

4-16Issue 5 June 1999

Page 110
Image 110