Lucent Technologies 555-232-102 manual Cell Antenna Unit, Procedure Installing Indoor CAUs

Models: 555-232-102

1 132
Download 132 pages 48.73 Kb
Page 70
Image 70
Cell Antenna Unit

Hardware Installation

Cell Antenna Unit

Procedure: Installing Indoor CAUsManual background NOTE:

Be sure to install the CAUs first and then wire back to the appropriate WFBs.

The CAU is an optional remote antenna that connects to a WFB to expand the coverage area. A maximum of four CAUs can be connected to a single WFB. Each CAU can be located as far as 100 cable feet from its associated WFB. Each CAU is connected to and powered by a WFB via a Lucent Technologies proprietary interface. Placement of the CAUs is based on the information provided by the installation map.

Indoor and outdoor CAUs are available. Indoor CAUs include the basic “indoor” CAU and the 559D Dipole CAU (DCAU). It is recommended that you use the 559D DCAU for new indoor installations. Also, if an “indoor” CAU is already in place, replace it with a 559D DCAU.

Outdoor CAUs include the 559B Outdoor CAU and the 559C Outdoor CAU. It is recommended that you use the 559C Outdoor CAU for new outdoor installations. Also, if a 559B Outdoor CAU is already in place, replace it with a 559C Outdoor CAU.

Procedure: Installing Indoor CAUs

The following procedure provides the steps necessary to install an indoor CAU.

There are two methods for mounting CAU(s). Use the following table to find the specific steps based on the particular configuration.

Manual backgroundManual background NOTE:

CAUs must not be mounted within one meter of one another to conform to the FCC Part 15 Rules.

3-30Issue 5 June 1999