DWBS Testing
Table
Error Code | Severity | Description/Recommendation |
|
|
|
0x892 | High | RC is busy receiving a WT package from the |
|
| MSS. |
|
| Wait for the download from the MSS to complete. |
|
| This should take about five minutes. |
|
|
|
0x893 | High | The RC flash does not contain a WT file to use |
|
| for an upgrade. |
|
| Check the |
|
| form at the bottom of page 2 for the RC circuit |
|
| pack. If the circuit pack is not listed, issue the |
|
| change system feature command and add it to |
|
| the list. Then issue the enable |
|
| [PPCSS] command. |
|
|
|
0x894 | High | The RC flash contains firmware for a different |
|
| model WT. |
|
| Download the correct firmware package. Then |
|
| check the |
|
| form at the bottom of page 2 for the RC circuit |
|
| pack. If the circuit pack is not listed, issue the |
|
| change system feature command and add it to |
|
| the list. Then issue the enable |
|
| [PPCSS] command. |
|
|
|
0x895 | High | The RC flash does not recognize the type of WT |
|
| that is connected. |
|
| The RC downloads only 9601 WTs and 9630 |
|
| Series WTs. |
|
|
|
0x897 | High | RC was requested to download a 9601 WT; |
|
| however, the RC has only the 9630 Series WT |
|
| firmware download package to send. |
|
| Download the 9601 WT package to the RC. |
|
|
|
0x898 | High | RC was requested to download a 9630 Series |
|
| WT; however, the RC has only the 9601 WT |
|
| firmware download package to send. |
|
| Download the 9630 Series WT package to the |
|
| RC. |
|
|
|
NOTE: The 9630 Series WT boot code firmware provides the automatic restart of the download process with low severity errors. The download process is attempted three times if the problem continues to occur. Thereafter, the error is declared as a high severity error, and user intervention is required.