Table 4-2. WT Download Error Codes (continued)

Error Code

Severity

Description/Recommendation

 

 

 

0x892

High

RC is busy receiving a WT package from the

 

 

MSS.

 

 

Wait for the download from the MSS to complete.

 

 

This should take about five minutes.

 

 

 

0x893

High

The RC flash does not contain a WT file to use

 

 

for an upgrade.

 

 

Check the Feature-Related System Parameters

 

 

form at the bottom of page 2 for the RC circuit

 

 

pack. If the circuit pack is not listed, issue the

 

 

change system feature command and add it to

 

 

the list. Then issue the enable wt-upgrade

 

 

[PPCSS] command.

 

 

 

0x894

High

The RC flash contains firmware for a different

 

 

model WT.

 

 

Download the correct firmware package. Then

 

 

check the Feature-Related System Parameters

 

 

form at the bottom of page 2 for the RC circuit

 

 

pack. If the circuit pack is not listed, issue the

 

 

change system feature command and add it to

 

 

the list. Then issue the enable wt-upgrade

 

 

[PPCSS] command.

 

 

 

0x895

High

The RC flash does not recognize the type of WT

 

 

that is connected.

 

 

The RC downloads only 9601 WTs and 9630

 

 

Series WTs.

 

 

 

0x897

High

RC was requested to download a 9601 WT;

 

 

however, the RC has only the 9630 Series WT

 

 

firmware download package to send.

 

 

Download the 9601 WT package to the RC.

 

 

 

0x898

High

RC was requested to download a 9630 Series

 

 

WT; however, the RC has only the 9601 WT

 

 

firmware download package to send.

 

 

Download the 9630 Series WT package to the

 

 

RC.

 

 

 

NOTE: The 9630 Series WT boot code firmware provides the automatic restart of the download process with low severity errors. The download process is attempted three times if the problem continues to occur. Thereafter, the error is declared as a high severity error, and user intervention is required.

4-14Issue 5 June 1999

Page 108
Image 108
Lucent Technologies 555-232-102 manual 2. WT Download Error Codes continued, Severity, Description/Recommendation