RECEIVE KEY SCAN CODE (54h)

Section - 7 Appendix

Johnson Millennium

02(h)

1/2 Effect Module

03(h)

3/4 Effect Module

04(h)

Whole Effect Module

RECEIVE KEY SCAN CODE (54h)

SYS_HEAD, 54(h), cc, F7(h)

ccCode for the Key Scan (note: there is only one byte, not two)

The Receive Key Scan Code procedure is used to emulate a button press on the front panel of the. See the Key Scan Code Maps (page 96) for a list of Key Scan codes.

RECEIVE HOLD KEY SCAN CODE (55h)

SYS_HEAD, 55(h), cc, 68, F7(h)

cc Code for the Key Scan (note: there is only one byte, not two)

68Time key is pressed expressed in 0.1 seconds increments (note: there is only one byte, not two)

The Receive Hold Key Scan Code procedure is used to emulate a button press and hold on the front panel of the Millennium. The device will respond with a Receive Key Accepted procedure.

RECEIVE KEY ACCEPTED (56h)

SYS_HEAD, 56(h), cc1, cc2, F7(h)

cc Code echoed for the Key Scan received. (00(h) if key is invalid)

The Receive Key Accepted procedure is sent from the Millennium in response and acceptance of a Receive Scan Code Key or Receive Hold Scan Code Key procedure but is ignored if received by the Millennium.

SELECT ONE PRESET (1Fh)

SYS_HEAD, 1F(h), yy1, yy2, zz1, zz2 F7(h)

When yy = 00(h)

User bank is selected

When yy = 01(h)

Factory bank is selected.

zz

The Preset number, 1-100 User (00-63(h)) or 1-191 Factory (00-BE(h))

This command behaves like a standard MIDI Preset Change command, except that it allows the selection of any preset in the Millennium without the use of mapping.